Matthias Wagner, Oliver Lang, Thomas Bauernfeind, Mario Huemer,
"Homogeneity Enforced Calibration of Stage Nonidealities for Pipelined ADCs"
, in IEEE Transactions on Circuits and Systems II: Express Briefs, Vol. 70, Nummer 4, IEEE, Seite(n) 1286-1290, 4-2023, ISSN: 1558-3791
Original Titel:
Homogeneity Enforced Calibration of Stage Nonidealities for Pipelined ADCs
Sprache des Titels:
Englisch
Original Kurzfassung:
Pipelined ADCs are fundamental components of various signal processing systems requiring high sampling rates and a high linearity. Over the past years, calibration techniques have been intensively investigated to increase the linearity In this work, we propose an equalization-based calibration technique which does not require knowledge of the ADC input signal for calibration. For that, a test signal and a scaled version of it are fed into the ADC sequentially, while only the corresponding output samples are used for calibration. Several test signal sources are possible, such as a SG or the SA itself. For the latter case, the presented method corresponds to a background calibration technique. Thus, slowly changing errors are tracked and calibrated continuously. Because of the low computational complexity of the calibration technique, it is suitable for an on-chip implementation. Ultimately, this work contains an analysis of the stability and convergence behavior as well as simulation results.
Sprache der Kurzfassung:
Englisch
Journal:
IEEE Transactions on Circuits and Systems II: Express Briefs